G.J.Chandran Complex, Coimbatore, Tamil Nadu
GST No. 33AAMHB0213L1ZO
Approx. Rs 45,800 / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Brand | ALLEN BRADLEY |
Manufacturer Series | 1756-A10 |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
ControlLogix I/O modules must be mounted in a ControlLogix chassis and each chassis requires a power supply. For more information about the 1756 Chassis and Power Supply options available for your system, see page 235. 1756 ControlLogix standard I/O modules require either a Removable Terminal Block (RTB) or a 1492 interface module (IFM) to connect all field-side wiring. RTBs and IFMs are not included with the I/O modules. They must be ordered separately. For more information about the RTBs and IFMs available for your system, see page 235 and page 236. 1756 ControlLogix safety I/O modules require either a specific Removable Terminal Block (RTB) or 1492 interface module (IFM) to connect al field-side wiring. 1756-IB16S and 1756-IB16SK (1756 ControlLogix 16-point Sinking Safety Input Modules) have been agency certified using only the ControlLogix RTBs (1756-TBCHS or 1756-TBS6HS). 1756-OBV8S and 1756-OBV8SK (ControlLogix 8-point Safety Bipolar/Sourcing Output Modules) have been agency certified using only the ControlLogix RTBs (1756-TBNHS and 1756-TBSHS). For information about the IFM module wiring systems that have been tested for use with 1756 Safety I/O modules, see Knowledgebase Technote, 1492 IFM Modules, Cables and Wiring Diagrams for 1756-IB16S, 1756-OBV8S Safety I/O Modules RTBs and IFMs are not included with the I/O modules. They must be ordered separately. For more information about the RTBs and IFMs available for your system, see page 235 and page 236. Any application that requires agency certification of the ControlLogix system by using other wiring termination methods may require application-specific approval by the certifying agency.
Approx. Rs 7,700 / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 1756-BA2 |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
ControlLogix I/O modules must be mounted in a ControlLogix chassis and each chassis requires a power supply. For more information about the 1756 Chassis and Power Supply options available for your system, see page 235. 1756 ControlLogix standard I/O modules require either a Removable Terminal Block (RTB) or a 1492 interface module (IFM) to connect all field-side wiring. RTBs and IFMs are not included with the I/O modules. They must be ordered separately. For more information about the RTBs and IFMs available for your system, see page 235 and page 236. 1756 ControlLogix safety I/O modules require either a specific Removable Terminal Block (RTB) or 1492 interface module (IFM) to connect al field-side wiring. 1756-IB16S and 1756-IB16SK (1756 ControlLogix 16-point Sinking Safety Input Modules) have been agency certified using only the ControlLogix RTBs (1756-TBCHS or 1756-TBS6HS). 1756-OBV8S and 1756-OBV8SK (ControlLogix 8-point Safety Bipolar/Sourcing Output Modules) have been agency certified using only the ControlLogix RTBs (1756-TBNHS and 1756-TBSHS). For information about the IFM module wiring systems that have been tested for use with 1756 Safety I/O modules, see Knowledgebase Technote, 1492 IFM Modules, Cables and Wiring Diagrams for 1756-IB16S, 1756-OBV8S Safety I/O Modules RTBs and IFMs are not included with the I/O modules. They must be ordered separately. For more information about the RTBs and IFMs available for your system, see page 235 and page 236. Any application that requires agency certification of the ControlLogix system by using other wiring termination methods may require application-specific approval by the certifying agency.
Approx. Rs 1.6 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 1756-CNBR |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
ControlLogix I/O modules must be mounted in a ControlLogix chassis and each chassis requires a power supply. For more information about the 1756 Chassis and Power Supply options available for your system, see page 235. 1756 ControlLogix standard I/O modules require either a Removable Terminal Block (RTB) or a 1492 interface module (IFM) to connect all field-side wiring. RTBs and IFMs are not included with the I/O modules. They must be ordered separately. For more information about the RTBs and IFMs available for your system, see page 235 and page 236. 1756 ControlLogix safety I/O modules require either a specific Removable Terminal Block (RTB) or 1492 interface module (IFM) to connect al field-side wiring. 1756-IB16S and 1756-IB16SK (1756 ControlLogix 16-point Sinking Safety Input Modules) have been agency certified using only the ControlLogix RTBs (1756-TBCHS or 1756-TBS6HS). 1756-OBV8S and 1756-OBV8SK (ControlLogix 8-point Safety Bipolar/Sourcing Output Modules) have been agency certified using only the ControlLogix RTBs (1756-TBNHS and 1756-TBSHS). For information about the IFM module wiring systems that have been tested for use with 1756 Safety I/O modules, see Knowledgebase Technote, 1492 IFM Modules, Cables and Wiring Diagrams for 1756-IB16S, 1756-OBV8S Safety I/O Modules RTBs and IFMs are not included with the I/O modules. They must be ordered separately. For more information about the RTBs and IFMs available for your system, see page 235 and page 236. Any application that requires agency certification of the ControlLogix system by using other wiring termination methods may require application-specific approval by the certifying agency.
Approx. Rs 2.18 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 1756-CNB |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
ControlLogix I/O modules must be mounted in a ControlLogix chassis and each chassis requires a power supply. For more information about the 1756 Chassis and Power Supply options available for your system, see page 235. 1756 ControlLogix standard I/O modules require either a Removable Terminal Block (RTB) or a 1492 interface module (IFM) to connect all field-side wiring. RTBs and IFMs are not included with the I/O modules. They must be ordered separately. For more information about the RTBs and IFMs available for your system, see page 235 and page 236. 1756 ControlLogix safety I/O modules require either a specific Removable Terminal Block (RTB) or 1492 interface module (IFM) to connect al field-side wiring. 1756-IB16S and 1756-IB16SK (1756 ControlLogix 16-point Sinking Safety Input Modules) have been agency certified using only the ControlLogix RTBs (1756-TBCHS or 1756-TBS6HS). 1756-OBV8S and 1756-OBV8SK (ControlLogix 8-point Safety Bipolar/Sourcing Output Modules) have been agency certified using only the ControlLogix RTBs (1756-TBNHS and 1756-TBSHS). For information about the IFM module wiring systems that have been tested for use with 1756 Safety I/O modules, see Knowledgebase Technote, 1492 IFM Modules, Cables and Wiring Diagrams for 1756-IB16S, 1756-OBV8S Safety I/O Modules RTBs and IFMs are not included with the I/O modules. They must be ordered separately. For more information about the RTBs and IFMs available for your system, see page 235 and page 236. Any application that requires agency certification of the ControlLogix system by using other wiring termination methods may require application-specific approval by the certifying agency.
Approx. Rs 1.82 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 1756-CN2 |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
ControlLogix I/O modules must be mounted in a ControlLogix chassis and each chassis requires a power supply. For more information about the 1756 Chassis and Power Supply options available for your system, see page 235. 1756 ControlLogix standard I/O modules require either a Removable Terminal Block (RTB) or a 1492 interface module (IFM) to connect all field-side wiring. RTBs and IFMs are not included with the I/O modules. They must be ordered separately. For more information about the RTBs and IFMs available for your system, see page 235 and page 236. 1756 ControlLogix safety I/O modules require either a specific Removable Terminal Block (RTB) or 1492 interface module (IFM) to connect al field-side wiring. 1756-IB16S and 1756-IB16SK (1756 ControlLogix 16-point Sinking Safety Input Modules) have been agency certified using only the ControlLogix RTBs (1756-TBCHS or 1756-TBS6HS). 1756-OBV8S and 1756-OBV8SK (ControlLogix 8-point Safety Bipolar/Sourcing Output Modules) have been agency certified using only the ControlLogix RTBs (1756-TBNHS and 1756-TBSHS). For information about the IFM module wiring systems that have been tested for use with 1756 Safety I/O modules, see Knowledgebase Technote, 1492 IFM Modules, Cables and Wiring Diagrams for 1756-IB16S, 1756-OBV8S Safety I/O Modules RTBs and IFMs are not included with the I/O modules. They must be ordered separately. For more information about the RTBs and IFMs available for your system, see page 235 and page 236. Any application that requires agency certification of the ControlLogix system by using other wiring termination methods may require application-specific approval by the certifying agency.
Approx. Rs 2.27 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 1756-CN2R |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
ControlLogix I/O modules must be mounted in a ControlLogix chassis and each chassis requires a power supply. For more information about the 1756 Chassis and Power Supply options available for your system, see page 235. 1756 ControlLogix standard I/O modules require either a Removable Terminal Block (RTB) or a 1492 interface module (IFM) to connect all field-side wiring. RTBs and IFMs are not included with the I/O modules. They must be ordered separately. For more information about the RTBs and IFMs available for your system, see page 235 and page 236. 1756 ControlLogix safety I/O modules require either a specific Removable Terminal Block (RTB) or 1492 interface module (IFM) to connect al field-side wiring. 1756-IB16S and 1756-IB16SK (1756 ControlLogix 16-point Sinking Safety Input Modules) have been agency certified using only the ControlLogix RTBs (1756-TBCHS or 1756-TBS6HS). 1756-OBV8S and 1756-OBV8SK (ControlLogix 8-point Safety Bipolar/Sourcing Output Modules) have been agency certified using only the ControlLogix RTBs (1756-TBNHS and 1756-TBSHS). For information about the IFM module wiring systems that have been tested for use with 1756 Safety I/O modules, see Knowledgebase Technote, 1492 IFM Modules, Cables and Wiring Diagrams for 1756-IB16S, 1756-OBV8S Safety I/O Modules RTBs and IFMs are not included with the I/O modules. They must be ordered separately. For more information about the RTBs and IFMs available for your system, see page 235 and page 236. Any application that requires agency certification of the ControlLogix system by using other wiring termination methods may require application-specific approval by the certifying agency.
Approx. Rs 7,200 / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 1756-CPR2 |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
ControlLogix I/O modules must be mounted in a ControlLogix chassis and each chassis requires a power supply. For more information about the 1756 Chassis and Power Supply options available for your system, see page 235. 1756 ControlLogix standard I/O modules require either a Removable Terminal Block (RTB) or a 1492 interface module (IFM) to connect all field-side wiring. RTBs and IFMs are not included with the I/O modules. They must be ordered separately. For more information about the RTBs and IFMs available for your system, see page 235 and page 236. 1756 ControlLogix safety I/O modules require either a specific Removable Terminal Block (RTB) or 1492 interface module (IFM) to connect al field-side wiring. 1756-IB16S and 1756-IB16SK (1756 ControlLogix 16-point Sinking Safety Input Modules) have been agency certified using only the ControlLogix RTBs (1756-TBCHS or 1756-TBS6HS). 1756-OBV8S and 1756-OBV8SK (ControlLogix 8-point Safety Bipolar/Sourcing Output Modules) have been agency certified using only the ControlLogix RTBs (1756-TBNHS and 1756-TBSHS). For information about the IFM module wiring systems that have been tested for use with 1756 Safety I/O modules, see Knowledgebase Technote, 1492 IFM Modules, Cables and Wiring Diagrams for 1756-IB16S, 1756-OBV8S Safety I/O Modules RTBs and IFMs are not included with the I/O modules. They must be ordered separately. For more information about the RTBs and IFMs available for your system, see page 235 and page 236. Any application that requires agency certification of the ControlLogix system by using other wiring termination methods may require application-specific approval by the certifying agency.
Approx. Rs 2.47 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 1756-EN4TR |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
Controller-to-local I/O modules or local communication modulesController-to-remote I/O or remote communication modules Controller-to-remote I/O (rack-optimized) modules Produced and consumed tags Controller access with the Studio 5000® environment Controller access with RSLinx® software for HMI or other applications
You indirectly determine the number of connections the controller uses by configuring the controller to communicate with other devices in
the system. The limit of connections ultimately resides in the communication module you use for the connection. If a message path routes through a communication module, the connection The DeviceNet network is open, providing connections between simple industrial devices, such as sensors and actuators, and higher-level devices, such as controllers and computers.The Data Highway Plus network supports messaging between devices. The remote IO-Link connects to remote I/O chassis and other intelligent devices. The 1756-DHRIO module supports messaging between devices on DH+™ networks. The remote I/O functionality enables the module to act as a scanner for transferring digital and block transfer data to and from remote I/O
Approx. Rs 2.42 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 1769-L30ER |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
Field Power Distributor Module - A field power distributor module can also be installed between embedded I/O modules and local expansion modules or between local expansion modules. The field power distributor module breaks the available field power current between the modules to its left and right. With the field power distributor module installed, the modules to its left can draw up 3 A of field power current. The modules to the right of the field power distributor can draw as much field power current as allowed by the field power distributor.the project is tested and ready for final validation, you apply the safety application signature and safety-lock the application. This process sets the safety task to a SIL 3 integrity level. The Compact GuardLogix enforces the SIL 3 integrity level. When safety memory is locked and protected, the safety logic cannot be modified and all safety functions operate with SIL 3 integrity. On the standard side of the Compact GuardLogix controller, all functions operate like a regular Logix controller. Thus online editing, forcing, and other activities are all allowed. Standard logic and external devices, like HMIs or other controllers, can read safety memory with this level of integration. This level of integration removes the need to condition safety memory for use elsewhere. The result is easy systemwide integration and the ability to display safety status on displays or marquees. Use Guard I/O™ modules for field device connectivity. For safety interlocking between Compact GuardLogix controllers, use Ethernet or ControlNet™ networks. Multiple Compact GuardLogix controllers can share safety data for zone to zone interlocking, or one Compact GuardLogix controller can use remote distributed safety I/O between different cells/areas.The expansion power supply breaks the available POINTBus backplane current between the modules to its left and right. With the expansion power supply installed, the modules to its left can draw up to 1 A of POINTBus backplane current. The modules to the right of the expansion power supply can draw as much current as the current provided by the expansion power supply. Additionally, the expansion power supply breaks the available field power current between the modules to its left and right. With the expansion power supply installed, the modules to its left can draw up to 3 A of field power current. The modules to the right of the expansion power supply can draw as much field power current as allowed by the expansion power supply
Approx. Rs 2.01 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 1769-L30ER-NSE |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
Field Power Distributor Module - A field power distributor module can also be installed between embedded I/O modules and local expansion modules or between local expansion modules. The field power distributor module breaks the available field power current between the modules to its left and right. With the field power distributor module installed, the modules to its left can draw up 3 A of field power current. The modules to the right of the field power distributor can draw as much field power current as allowed by the field power distributor.the project is tested and ready for final validation, you apply the safety application signature and safety-lock the application. This process sets the safety task to a SIL 3 integrity level. The Compact GuardLogix enforces the SIL 3 integrity level. When safety memory is locked and protected, the safety logic cannot be modified and all safety functions operate with SIL 3 integrity. On the standard side of the Compact GuardLogix controller, all functions operate like a regular Logix controller. Thus online editing, forcing, and other activities are all allowed. Standard logic and external devices, like HMIs or other controllers, can read safety memory with this level of integration. This level of integration removes the need to condition safety memory for use elsewhere. The result is easy systemwide integration and the ability to display safety status on displays or marquees. Use Guard I/O™ modules for field device connectivity. For safety interlocking between Compact GuardLogix controllers, use Ethernet or ControlNet™ networks. Multiple Compact GuardLogix controllers can share safety data for zone to zone interlocking, or one Compact GuardLogix controller can use remote distributed safety I/O between different cells/areas.The expansion power supply breaks the available POINTBus backplane current between the modules to its left and right. With the expansion power supply installed, the modules to its left can draw up to 1 A of POINTBus backplane current. The modules to the right of the expansion power supply can draw as much current as the current provided by the expansion power supply. Additionally, the expansion power supply breaks the available field power current between the modules to its left and right. With the expansion power supply installed, the modules to its left can draw up to 3 A of field power current. The modules to the right of the expansion power supply can draw as much field power current as allowed by the expansion power supply
Approx. Rs 2.93 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 1769-L30ERM |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
Field Power Distributor Module - A field power distributor module can also be installed between embedded I/O modules and local expansion modules or between local expansion modules. The field power distributor module breaks the available field power current between the modules to its left and right. With the field power distributor module installed, the modules to its left can draw up 3 A of field power current. The modules to the right of the field power distributor can draw as much field power current as allowed by the field power distributor.the project is tested and ready for final validation, you apply the safety application signature and safety-lock the application. This process sets the safety task to a SIL 3 integrity level. The Compact GuardLogix enforces the SIL 3 integrity level. When safety memory is locked and protected, the safety logic cannot be modified and all safety functions operate with SIL 3 integrity. On the standard side of the Compact GuardLogix controller, all functions operate like a regular Logix controller. Thus online editing, forcing, and other activities are all allowed. Standard logic and external devices, like HMIs or other controllers, can read safety memory with this level of integration. This level of integration removes the need to condition safety memory for use elsewhere. The result is easy systemwide integration and the ability to display safety status on displays or marquees. Use Guard I/O™ modules for field device connectivity. For safety interlocking between Compact GuardLogix controllers, use Ethernet or ControlNet™ networks. Multiple Compact GuardLogix controllers can share safety data for zone to zone interlocking, or one Compact GuardLogix controller can use remote distributed safety I/O between different cells/areas.The expansion power supply breaks the available POINTBus backplane current between the modules to its left and right. With the expansion power supply installed, the modules to its left can draw up to 1 A of POINTBus backplane current. The modules to the right of the expansion power supply can draw as much current as the current provided by the expansion power supply. Additionally, the expansion power supply breaks the available field power current between the modules to its left and right. With the expansion power supply installed, the modules to its left can draw up to 3 A of field power current. The modules to the right of the expansion power supply can draw as much field power current as allowed by the expansion power supply
Approx. Rs 3.59 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 1769-L32E |
Output Type | Digital |
Communication Port | Ethernet |
Usage/Application | Industrial |
Field Power Distributor Module - A field power distributor module can also be installed between embedded I/O modules and local expansion modules or between local expansion modules. The field power distributor module breaks the available field power current between the modules to its left and right. With the field power distributor module installed, the modules to its left can draw up 3 A of field power current. The modules to the right of the field power distributor can draw as much field power current as allowed by the field power distributor.the project is tested and ready for final validation, you apply the safety application signature and safety-lock the application. This process sets the safety task to a SIL 3 integrity level. The Compact GuardLogix enforces the SIL 3 integrity level. When safety memory is locked and protected, the safety logic cannot be modified and all safety functions operate with SIL 3 integrity. On the standard side of the Compact GuardLogix controller, all functions operate like a regular Logix controller. Thus online editing, forcing, and other activities are all allowed. Standard logic and external devices, like HMIs or other controllers, can read safety memory with this level of integration. This level of integration removes the need to condition safety memory for use elsewhere. The result is easy systemwide integration and the ability to display safety status on displays or marquees. Use Guard I/O™ modules for field device connectivity. For safety interlocking between Compact GuardLogix controllers, use Ethernet or ControlNet™ networks. Multiple Compact GuardLogix controllers can share safety data for zone to zone interlocking, or one Compact GuardLogix controller can use remote distributed safety I/O between different cells/areas.The expansion power supply breaks the available POINTBus backplane current between the modules to its left and right. With the expansion power supply installed, the modules to its left can draw up to 1 A of POINTBus backplane current. The modules to the right of the expansion power supply can draw as much current as the current provided by the expansion power supply. Additionally, the expansion power supply breaks the available field power current between the modules to its left and right. With the expansion power supply installed, the modules to its left can draw up to 3 A of field power current. The modules to the right of the expansion power supply can draw as much field power current as allowed by the expansion power supply
Approx. Rs 23,200 / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 1769-OA8 |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
Approx. Rs 2.61 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 1769-L36ERM |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
Approx. Rs 2.83 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 1769-L33ERM |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
Approx. Rs 33,200 / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 1769-OA16 |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
Approx. Rs 13,500 / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 1769-OB16 |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
Approx. Rs 36,600 / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 1769-OB32T |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
Approx. Rs 88,900 / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 5069-L306ER |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
Approx. Rs 1.82 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 5069-L310ER |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
Approx. Rs 3.26 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 5069-L320ERM |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
Approx. Rs 21,000 / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 5069-OB8 |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
Approx. Rs 22,200 / PieceGet Latest Price
Product BrochureProduct Details:Number of Channels | 32 |
Brand | Schneider |
Material | Programmable Control Module |
Usage/Application | Industrial |
Warranty | 6 months |
Approx. Rs 9,800 / PieceGet Latest Price
Product BrochureProduct Details:Number of Channels | 16 |
Brand | Schneider |
Usage/Application | Industrial |
Warranty | 6 months |
Model Name/Number | TM3DI16K |
Approx. Rs 1.44 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Mounting Type | DIN Rail |
Power | 24V DC |
Output Type | Digital |
Dimensions (H x D x W) | 90 mm x 75 mm x 31 mm |
Brand | Omron |
Manufacturer Series | Omron CJ2M-CPU32 |
I/O Points | 2560 |
Approx. Rs 1.99 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 1756-EN2T |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
Controller-to-local I/O modules or local communication modulesController-to-remote I/O or remote communication modules Controller-to-remote I/O (rack-optimized) modules Produced and consumed tags Controller access with the Studio 5000® environment Controller access with RSLinx® software for HMI or other applications
You indirectly determine the number of connections the controller uses by configuring the controller to communicate with other devices in
the system. The limit of connections ultimately resides in the communication module you use for the connection. If a message path routes through a communication module, the connection The DeviceNet network is open, providing connections between simple industrial devices, such as sensors and actuators, and higher-level devices, such as controllers and computers.The Data Highway Plus network supports messaging between devices. The remote IO-Link connects to remote I/O chassis and other intelligent devices. The 1756-DHRIO module supports messaging between devices on DH+™ networks. The remote I/O functionality enables the module to act as a scanner for transferring digital and block transfer data to and from remote I/O
Approx. Rs 2.77 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 1756-EN3TR |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
Controller-to-local I/O modules or local communication modulesController-to-remote I/O or remote communication modules Controller-to-remote I/O (rack-optimized) modules Produced and consumed tags Controller access with the Studio 5000® environment Controller access with RSLinx® software for HMI or other applications
You indirectly determine the number of connections the controller uses by configuring the controller to communicate with other devices in
the system. The limit of connections ultimately resides in the communication module you use for the connection. If a message path routes through a communication module, the connection The DeviceNet network is open, providing connections between simple industrial devices, such as sensors and actuators, and higher-level devices, such as controllers and computers.The Data Highway Plus network supports messaging between devices. The remote IO-Link connects to remote I/O chassis and other intelligent devices. The 1756-DHRIO module supports messaging between devices on DH+™ networks. The remote I/O functionality enables the module to act as a scanner for transferring digital and block transfer data to and from remote I/O
Approx. Rs 2.15 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 1756-EN2TR |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
Controller-to-local I/O modules or local communication modulesController-to-remote I/O or remote communication modules Controller-to-remote I/O (rack-optimized) modules Produced and consumed tags Controller access with the Studio 5000® environment Controller access with RSLinx® software for HMI or other applications
You indirectly determine the number of connections the controller uses by configuring the controller to communicate with other devices in
the system. The limit of connections ultimately resides in the communication module you use for the connection. If a message path routes through a communication module, the connection The DeviceNet network is open, providing connections between simple industrial devices, such as sensors and actuators, and higher-level devices, such as controllers and computers.The Data Highway Plus network supports messaging between devices. The remote IO-Link connects to remote I/O chassis and other intelligent devices. The 1756-DHRIO module supports messaging between devices on DH+™ networks. The remote I/O functionality enables the module to act as a scanner for transferring digital and block transfer data to and from remote I/O
Approx. Rs 1.75 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 1769-L35E |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
Approx. Rs 3.95 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Brand | ALLEN BRADLEY |
Manufacturer Series | 5069-L330ER |
Output Type | Digital |
Usage/Application | Industrial |
Approx. Rs 23,300 / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Usage | for Industrial Machinery |
Brand | Allen Bradley |
Model Name/Number | 20BC140A0ANNANC0 |
Input Phase | 1 - Phase |
Voltage | 200 - 240 V |
Warranty | 12 Months |
Communication Ports | External |
Mounting Type | Panel Mount |
Approx. Rs 2.78 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Usage | for Industrial Machinery |
Brand | Allen Bradley |
Model Name/Number | 20BC170A0ANNANC0 |
Input Phase | 1 - Phase |
Voltage | 200 - 240 V |
Warranty | 12 Months |
Mounting Type | Panel Mount |
Approx. Rs 1.31 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Usage | for Industrial Machinery |
Brand | Allen Bradley |
Model Name/Number | 20BC170A3AYNANC0 |
Input Phase | 1 - Phase |
Warranty | 12 Months |
Communication Ports | External |
Mounting Type | Panel Mount |
Approx. Rs 90,200 / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Usage | for Industrial Machinery |
Brand | Allen Bradley |
Model Name/Number | 25BE9P9N104 |
Input Phase | 1 - Phase |
Warranty | 12 Months |
Communication Ports | External |
Approx. Rs 21,000 / PieceGet Latest Price
Product BrochureProduct Details:Number of Channels | 8 |
Material | Insulating Materials |
Brand | Schneider |
Usage/Application | Industrial |
Warranty | 1 Year Company Warranty |
Model Name/Number | TM3TI8G |
Input Current | 220 V |
Approx. Rs 2.24 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 1769-L33ER |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
The 1769-L33ER controller is an Allen-Bradley/Rockwell Automation controller from the CompactLogix series and the CompactLogix 5370 product line. It can be mounted on a panel or a DIN Rail, and its mounting base will affect its shock ratings. The 1769-L33ER controller can tolerate 20 g of operating shock on a DIN Rail and 30 g of operating shock on a panel. Its maximum operating temperature is 140 degrees Fahrenheit and its maximum storage and transport temperature is 185 degrees Fahrenheit. The 1769-L33ER controller can handle 32 periodic or continuous tasks at a time and it can handle up to 100 programs per task.
The 1769-L33ER CompactLogix 5370 controller by Allen-Bradley is a compact Logix controller. The 1769-L33ER can communicate with the controller or other devices through the Ethernet port. This controller has built-in user memory of 2 MB. It is packaged with an optional non-volatile memory card which amounts to 1GB, thay may be expanded up to 2GB. The 1769-L33ER can support Sixteen (16) I/O modules with a maximum of Three (3) I/O banks connected by appropriate expansion cables.The 1769-L33ER has a draw current of 5 Volts DC at 560 mA across 4 power supply modules and has a maximum power dissipation of 4.5 Watts. It has a 500 mA @ 5VDC backplane current draw and a maximum bus insulation 30 Volts. The 1769-L33ER can be mounted using either a DIN rail or panel mounting.Approx. Rs 80,800 / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Brand | ALLEN BRADLEY |
Manufacturer Series | 1769-L35CR |
Output Type | Digital |
Usage/Application | Industrial |
A field power distributor module can also be installed between embedded I/O modules and local expansion modules or between local expansion modules. The field power distributor module breaks the available field power current between the modules to its left and right. With the field power distributor module installed, the modules to its left can draw up 3 A of field power current. The modules to the right of the field power distributor can draw as much field power current as allowed by the field power distributor.the project is tested and ready for final validation, you apply the safety application signature and safety-lock the application. This process sets the safety task to a SIL 3 integrity level. The Compact GuardLogix enforces the SIL 3 integrity level. When safety memory is locked and protected, the safety logic cannot be modified and all safety functions operate with SIL 3 integrity. On the standard side of the Compact GuardLogix controller, all functions operate like a regular Logix controller. Thus online editing, forcing, and other activities are all allowed. Standard logic and external devices, like HMIs or other controllers, can read safety memory with this level of integration. This level of integration removes the need to condition safety memory for use elsewhere. The result is easy systemwide integration and the ability to display safety status on displays or marquees. Use Guard I/O™ modules for field device connectivity. For safety interlocking between Compact GuardLogix controllers, use Ethernet or ControlNet™ networks. Multiple Compact GuardLogix controllers can share safety data for zone to zone interlocking, or one Compact GuardLogix controller can use remote distributed safety I/O between different cells/areas.The expansion power supply breaks the available POINTBus backplane current between the modules to its left and right. With the expansion power supply installed, the modules to its left can draw up to 1 A of POINTBus backplane current. The modules to the right of the expansion power supply can draw as much current as the current provided by the expansion power supply. Additionally, the expansion power supply breaks the available field power current between the modules to its left and right. With the expansion power supply installed, the modules to its left can draw up to 3 A of field power current. The modules to the right of the expansion power supply can draw as much field power current as allowed by the expansion power supply
Approx. Rs 19,300 / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 1769-OB8 |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
Approx. Rs 21,500 / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Brand | ALLEN BRADLEY |
Manufacturer Series | 1756-BATM |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
ControlLogix I/O modules must be mounted in a ControlLogix chassis and each chassis requires a power supply. For more information about the 1756 Chassis and Power Supply options available for your system, see page 235. 1756 ControlLogix standard I/O modules require either a Removable Terminal Block (RTB) or a 1492 interface module (IFM) to connect all field-side wiring. RTBs and IFMs are not included with the I/O modules. They must be ordered separately. For more information about the RTBs and IFMs available for your system, see page 235 and page 236. 1756 ControlLogix safety I/O modules require either a specific Removable Terminal Block (RTB) or 1492 interface module (IFM) to connect al field-side wiring. 1756-IB16S and 1756-IB16SK (1756 ControlLogix 16-point Sinking Safety Input Modules) have been agency certified using only the ControlLogix RTBs (1756-TBCHS or 1756-TBS6HS). 1756-OBV8S and 1756-OBV8SK (ControlLogix 8-point Safety Bipolar/Sourcing Output Modules) have been agency certified using only the ControlLogix RTBs (1756-TBNHS and 1756-TBSHS). For information about the IFM module wiring systems that have been tested for use with 1756 Safety I/O modules, see Knowledgebase Technote, 1492 IFM Modules, Cables and Wiring Diagrams for 1756-IB16S, 1756-OBV8S Safety I/O Modules RTBs and IFMs are not included with the I/O modules. They must be ordered separately. For more information about the RTBs and IFMs available for your system, see page 235 and page 236. Any application that requires agency certification of the ControlLogix system by using other wiring termination methods may require application-specific approval by the certifying agency.
Approx. Rs 2.7 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Mounting Type | Panel Mount |
Brand | Allen Bradley |
Manufacturer Series | 1756-DHRIO |
Output Type | Digital |
Communication Port | External |
Usage/Application | Industrial |
ControlLogix I/O modules must be mounted in a ControlLogix chassis and each chassis requires a power supply. For more information about the 1756 Chassis and Power Supply options available for your system, see page 235. 1756 ControlLogix standard I/O modules require either a Removable Terminal Block (RTB) or a 1492 interface module (IFM) to connect all field-side wiring. RTBs and IFMs are not included with the I/O modules. They must be ordered separately. For more information about the RTBs and IFMs available for your system, see page 235 and page 236. 1756 ControlLogix safety I/O modules require either a specific Removable Terminal Block (RTB) or 1492 interface module (IFM) to connect al field-side wiring. 1756-IB16S and 1756-IB16SK (1756 ControlLogix 16-point Sinking Safety Input Modules) have been agency certified using only the ControlLogix RTBs (1756-TBCHS or 1756-TBS6HS). 1756-OBV8S and 1756-OBV8SK (ControlLogix 8-point Safety Bipolar/Sourcing Output Modules) have been agency certified using only the ControlLogix RTBs (1756-TBNHS and 1756-TBSHS). For information about the IFM module wiring systems that have been tested for use with 1756 Safety I/O modules, see Knowledgebase Technote, 1492 IFM Modules, Cables and Wiring Diagrams for 1756-IB16S, 1756-OBV8S Safety I/O Modules RTBs and IFMs are not included with the I/O modules. They must be ordered separately. For more information about the RTBs and IFMs available for your system, see page 235 and page 236. Any application that requires agency certification of the ControlLogix system by using other wiring termination methods may require application-specific approval by the certifying agency.
Explore More Products
© Lakshmi Electronics. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited