Smps Power Supply

Pioneers in the industry, we offer omron s8vk-c smps, 3 phase meanwell smps, 3 phase omron smps and meanwell led smps from India.

Omron S8VK-C SMPS

REQUEST CALLBACK

Omron  S8VK-C SMPS
  • Omron  S8VK-C SMPS
  • Omron  S8VK-C SMPS
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 1,000 / PieceGet Latest Price

Product Brochure
Product Details:
Minimum Order Quantity5 Piece
Output Voltage24V
Usage/ApplicationVoltage Exchanger
Input Voltage Range240 VAC
BrandOmron
Ripple Voltage24 V
Efficiency90%
DesignSmps
Display TypeLED
Input Current100 A
Output TypeSingle
Humidity90%
Model Name/NumberS8VK-C
Ambient Temperature60 Degree C
Storage Temperature Range65 Degree C

Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the
rise in the internal temperature of the Power Supply may result in ignition or burning.
*2. For a cold start at 25°C. Refer to Engineering Data on Catalog for details.
*3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +15% of the voltage adjustment
range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that
the load is not damaged.
*4. A characteristic when the ambient operating temperature is between –25 to 60°C.
*5. To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON.
*6. Safety Standard for a DC Input
The following safety standards apply to a DC input: UL No. 62368-1, cUR (CSA C22.2 No.62368-1), EN 62477-1, EN62368-1.
For a DC input, safety is ensured by external fuse.
Select an external fuse the meets the following conditions.
S8VK-C06024: 350 VDC min, 6A
S8VK-C12024: 350 VDC min, 8A
S8VK-C24024: 350 VDC min, 8A
S8VK-C48024: 350 VDC min, 12A
7. The value is when both rated output voltage and rated output current are satisfied.

  • Universal input for worldwide applications: 100 to 240 VAC (85 to 264 VAC) 
  •  DC input can be available: 90 to 350 VDC 
  •  Operation temperature range: –25 to 60 °C 
  •  Compact Dimension for small space 
  •  Flexible installation by special mounting brackets 
  • Safety standards: UL508/62368-1, CSA C22.2 No.107.1/62368-1 EN62477-1, EN62368-1 
  • EMS: Conform to EN61204-3 EMI: EN55011 Class A
  • Overvoltage Protection Consider the possibility of an overvoltage and design the system so that the load will not be subjected to an excessive voltage even if the feedback circuit in the Power Supply fails. If an excessive voltage that is approximately 130% of the rated voltage or more is output, the output voltage is shut OFF. Reset the input power by turning it OFF for at least three minutes and then turning it back ON again.
  • Overload Protection The load and the power supply are automatically protected from overcurrent damage by this function. Overload protection is activated if the output current rises above 105% of the rated current. When the output current returns within the rated range overload protection is automatically cleared.
  • Two phases application for Single phase models For All Single phase Models, S8VK-C Basically OMRON single phase power supply can be used on two phases of a 3–phase-system when some of conditions satisfy like below
The supplying voltage is below the maximum rated input. OMRON Power supply allows the input voltage equivalent or less than 240 VAC+10%. Please confirm the input voltage between two lines if the input voltage satisfies this condition before connecting. 
The external protector is needed on N input line to secure a safety. N line has no protection of a fuse internally. An appropriate fuse or circuit breaker should be connected on N input line like the following.
  • Used to warn of the risk of electric shock under specific conditions.
  • Used to warn of the risk of minor injury caused by high temperatures.
  • Used for general mandatory action precautions for which there is no specified symbol.
  • Use to indicate prohibition when there is a risk of minor injury from electrical shock or other source if the product is disassembled.  
Yes! I am Interested

3 Phase Meanwell Smps

REQUEST CALLBACK

3 Phase Meanwell Smps
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 3,000 / PieceGet Latest Price

Product Brochure
Product Details:
Minimum Order Quantity5 Piece
Output Voltage24V
Usage/ApplicationVoltage Exchanger
Input Voltage Range480 V
BrandMeanwell
Efficiency90%
Input Voltage220 VAC
DesignSmps
Output Current10 A
Display TypeLED
Output TypeSingle
Operating Temperature80 Degree C
Frequency50 Hz
Humidity90%
Temperature Cofficient0.05%
No.Of Phase3 Phase
Model NumberTDR-240-24

Wattage:
Input: 340-550
Output: 24, 48
L: 63
W: 125.2
H: 113.5
Warranty: 3


Yes! I am Interested

3 Phase Omron SMPS

REQUEST CALLBACK

3 Phase Omron SMPS
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 2,200 / PieceGet Latest Price

Product Brochure
Product Details:
Minimum Order Quantity5 Piece
Output Voltage24V
Usage/ApplicationVoltage Exchanger
Input Voltage Range400 VAC
BrandOmron
Efficiency100%
DesignSmps
Output Current5 A
Display TypeLED
Output TypeSingle
Weight650gm
Frequency50 Hz
Humidity95%
Ambient Temperature70 Degree C
No.Of Phase3 Phase
Boost Current6 A
Model No.S8VK-T24024

Type Book type
Mounting method DIN rail
Phase Three
Power output 240 W

Rated output current 10 A
Power boost ratio 120 %
Temperature range -40-70 °C
Terminal Screw
Rated supply voltage at AC 50 Hz 380-480 V
Allowable supply voltage AC 320-576 V
Allowable supply voltage DC 450-810 V
Width 60 mm
Height 125 mm
Depth 140 mm


  • The value is when both rated output voltage and rated output current are satisfied. 
  •  Do not use an inverter output for the product. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the product may result in ignition or burning. If the input is connected to a UPS, do not connect a UPS with a square-wave output. Doing so will cause the internal temperature of the product to increase, possibly causing smoking or burning. 
  •  The value is determined according to the Electrical Appliances and Material Safety Act. 
  • Values for a cold start at 25°C. Refer to Inrush Current, Startup Time, Output Hold Time on page 9 for details. 
  •  If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the voltage adjustment range. When adjusting the output voltage, confirm the actual output voltage from the product and be sure that the load is not damaged. 
  •  The value is when both rated output voltage and rated output current are satisfied. A characteristic when the ambient operating temperature is 25°C. 
  •  This is the maximum variation in the output voltage when the input voltage is gradually changed within the allowable input voltage range at the rated output voltage and rated output current. 
  •  When the input voltage is 380 to 480 VAC, this is the maximum variation in the output voltage when the output current is gradually changed within the range of 0 A to the rated output current. 
  •  The value is when rated output voltage, rated output current, and room temperature (25°C) are satisfied. Refer to Inrush Current, Startup Time, Output Hold Time on page 9 for details. *10. At -40 to -25°C, time will be required before the rated output voltage is output after the input voltage is input. Also, the ripple noise value may exceed the value shown in the above table. (3-phase 380 to 480 VAC input only) 
  •  MTBF is calculated according to JEITA RCR-9102. 
  •  Refer to Recommended Replacement Periods and Periodic Replacement for Preventive Maintenance on page 18 for details.  When using 2-phase input, conforms to EN 61000-3-2 under the following condition 960W: At the rated output voltage, and 80% or less than the rated output current
  • Overvoltage will be detected to prevent the load from being subjected to excessive voltage when the feedback circuit in the Power Supply fails, etc. If an excessive voltage that is approximately 130% of the rated voltage or more is output, the output voltage is shut OFF. Reset the input power by turning it OFF for at least five minutes and then turning it back ON again.
  • The load and the product are automatically protected from overcurrent damage by this function.
Yes! I am Interested

Meanwell LED SMPS

REQUEST CALLBACK

Meanwell LED SMPS
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 2,500 / PieceGet Latest Price

Product Brochure
Product Details:
Minimum Order Quantity5 Piece
Output Voltage24V
Input Voltage Range500 VAC
Usage/ApplicationVoltage Exchanger
Ripple Voltage300 V
BrandMeanwell
Efficiency90%
DesignSmps
Output Current10 A
Display TypeLED
Input Current2.0 A
Output TypeSingle
Mounting StyleDIN
Frequency50 Hz
MaterialAluminium
Model NumberWDR-240-24
No.Of Phase3 Phase

Wattage: 
Input: 180-550
Output: 24, 48
L: 63
W: 125.2
H: 113.5
Warranty: 3

  • Use Copper Wire Only Minimum 75 Degree C
  • Max. Surrounding Air Temperature 50 Degree C
  • Install In A Pollution Degree 2 Environment
Yes! I am Interested

 
X


Explore More Products

Contact via E-mail
Contact via SMS
Mohan (Sales Manager)
Lakshmi Electronics
No.11/H2, C.J.Chandran Complex, Head Quarters Road , Avinashi Road, Uppili Palayam,G.J.Chandran Complex
Coimbatore - 641018, Tamil Nadu, India
Call Us: 
Call Response Rate: 77%
Share Us :



Home  |   About Us   |  Our Products  |  Site Map  |   Contact Us

© Lakshmi Electronics. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Lakshmi Electronics